Fridge temperature log: a template and what to record
Check every fridge and freezer at least at opening and at closing, write down the temperature, your initials and what you did if it was too warm. Below is a log you can copy.
A temperature log is the simplest proof that your chilled storage works. It is also one of the first things an Environmental Health Officer asks to see. Read every fridge and freezer at fixed moments, write it down, and note what you did whenever a reading was out. That last column is the one that matters most.
The limits you are working to
In England, the Food Safety and Hygiene (England) Regulations 2013 require food that needs chilling to be kept at 8 °C or below. Wales and Northern Ireland have the same limit in their own regulations. The Food Standards Agency advises setting fridges to 5 °C or below, so that food stays under 8 °C even when the door is opened often during service. Scotland's regulations require food to be kept in a fridge or a cool ventilated place without naming a figure, so there 8 °C is a recommendation rather than the law. Food Standards Scotland's CookSafe pack gives the guidance.
For freezers the usual target in the FSA's Safer Food, Better Business pack is -18 °C or colder. Hot food that is held for service has to stay at 63 °C or above.
The template
One sheet per week, one row per day. Add a column for every fridge and freezer you have, and number the units so there is no doubt which one was read.
| Date | Time | Fridge 1 | Fridge 2 | Freezer 1 | Initials | Action if out of range |
|---|---|---|---|---|---|---|
| [date] | Opening | [°C] | [°C] | [°C] | [ ] | [ ] |
| [date] | Closing | [°C] | [°C] | [°C] | [ ] | [ ] |
Filled in, a day with a problem looks like this:
| Date | Time | Fridge 1 | Fridge 2 | Freezer 1 | Initials | Action if out of range |
|---|---|---|---|---|---|---|
| Mon 3 Nov | 08:00 | 3 °C | 4 °C | -20 °C | KM | |
| Mon 3 Nov | 22:30 | 4 °C | 9 °C | -19 °C | JT | Fridge 2 door left ajar after delivery. Probed food at 7 °C, moved to fridge 1, rechecked fridge 2 at 23:15: 5 °C |
How to take a reading that means something
- Read the display, then check it. A built-in display shows the air temperature where the sensor sits. Check it now and then against a probe thermometer in a glass of water or in a food item.
- Probe the food when the air reads high. Air warms up fast when the door opens; food takes longer. A high air reading straight after service is not yet a food safety problem, but write down the food temperature to show you checked.
- Read at the same moments every day. Opening and closing is the minimum. A reading just after a big delivery or a busy service tells you more than one in a quiet hour.
- Calibrate your probe. In iced water it should read close to 0 °C, in boiling water close to 100 °C. Note the check on the log.
When a reading is too high
- Probe the food in the unit.
- Move what is still within limits to a unit that works.
- Judge food that has been above the limit: how long, how warm, what kind of food. When in doubt, throw it away.
- Find the cause: door, overloading, a blocked fan, a faulty seal. Call an engineer if you cannot fix it.
- Write all of it in the action column, with a time and a recheck.
A hot holding log works the same way
If you keep food hot for service, add a second sheet with the item, the time it went into the hot hold, a probe reading every two hours and the action taken. Food that has been below 63 °C for less than two hours can be reheated until steaming hot and put back into hot holding once, or chilled quickly to 8 °C or below. After two hours, throw it away. These logs sit next to your HACCP plan, where chilled storage and hot holding are the critical control points they prove.
Frequently asked questions
What temperature should a commercial fridge be in the UK?
In England, Wales and Northern Ireland, chilled food has to be kept at 8 °C or below by law; in Scotland that figure is recommended. The Food Standards Agency advises setting fridges to 5 °C or below so that food stays under the limit during busy periods.
How often should fridge temperatures be recorded?
At least at opening and at closing every day. Many kitchens add a reading after big deliveries or service peaks. Safer Food, Better Business asks for daily checks signed off in the diary.
What should a fridge temperature log include?
The date and time, the reading for each numbered unit, the initials of the person who checked, and what was done when a reading was out of range, including a recheck.
What temperature should a freezer be?
The usual target in the Food Standards Agency's Safer Food, Better Business pack is -18 °C or colder.
Do I need to keep temperature records by law?
The law requires a food safety management system based on HACCP and records that fit your business. Temperature records are the normal way to show that chilled storage, a critical control point, is under control, and inspectors will expect to see them.